Making Primer Stocks
Gregory Broussard
Revised: 8/1/07
(Please use, change and disseminate freely!)
- When receiving a new lyophilized primer start by making a 100 µM stock. Multiply the number of nmoles printed on the tube by 10. This is the number of µl of TE to add to the tube to get a 100 µM stock. Make this stock directly in the tube containing the primer.
- Make a 10 µM working stock by making a 1:10 dilution of the 100 µM stock. Use this for your PCR reactions
Leave a Comment